feat(family-16): add ValueArea + InitialBalance + OpeningRange (#52)

* feat(family-16): add ValueArea + InitialBalance + OpeningRange

Opens family #16 (Market Profile) with the three OHLCV-compatible scalar /
multi-output indicators:

- ValueArea(period, bin_count, value_area_pct) -> {poc, vah, val}.
  Rolling bin-approximation volume profile over the last `period`
  candles. Each candle's volume is spread uniformly across [low, high];
  POC is the bin with highest cumulative volume; the value area expands
  symmetrically from POC and always absorbs the higher-volume neighbour
  next, until `value_area_pct` (default 0.70) of total volume is
  enclosed. Defaults (20, 50, 0.70).

- InitialBalance(period) -> {high, low}. Tracks session-opening high
  and low over the first `period` bars, then locks. Default period = 12
  (one-hour IB on 5-minute bars for US equities). Callers MUST invoke
  reset() at every session boundary, otherwise IB stays fixed for the
  lifetime of the instance.

- OpeningRange(period) -> {high, low, breakout_distance}. Same
  lock-after-N-bars semantics as IB with a shorter default period
  (6 = 30 min on 5-minute bars) and a third output that tracks
  close - or_mid (positive above the range mid, negative below).

Histogram-output Market Profile variants (Volume Profile, VPVR,
Composite Profile) are deferred because they need a new histogram
output API layer rather than fixed-arity scalars. Tick-data-only
variants (TPO Profile, Single Print, Order Flow Delta, Cumulative
Delta, Volume-Weighted Open) are out of scope because `wickra-data`
does not currently expose tick / L2 data.

All four bindings (Rust core, Python, Node, WASM) ship the new
indicators with parity tests; benches added; fuzz target extended.
Counter 71 -> 74 across 8 -> 9 families. cargo check --workspace
--all-features green.

* fix(family-16): cover cold paths in InitialBalance + ValueArea

InitialBalance::value() public getter had no test covering the post-update
Some(...) branch — extended accessors_and_metadata to call value() after one
update. ValueArea single-print bar path (c.high == c.low) was unreachable in
existing tests since the only single-print test used a uniform 100-price
window which exits early via the span == 0 guard; added a mixed-window test
that triggers the c.high <= c.low branch directly. The (None, None) arm of
the expansion match was by-construction unreachable (the loop condition
already requires at least one neighbour) and has been folded into an
if/else.
This commit is contained in:
kingchenc
2026-05-26 00:14:30 +02:00
committed by GitHub
parent 05fcdd9a5e
commit 9b8e1346ed
20 changed files with 1946 additions and 35 deletions
+26
View File
@@ -88,6 +88,32 @@ def test_candle_tuple_input_supported():
assert v is not None
def test_initial_balance_reset_unlocks():
ib = ta.InitialBalance(2)
assert not ib.is_ready()
ib.update((101.0, 102.0, 100.0, 101.0, 0.0, 0))
ib.update((102.0, 103.0, 101.0, 102.0, 0.0, 1))
assert ib.is_ready()
assert ib.is_locked()
ib.reset()
assert not ib.is_ready()
assert not ib.is_locked()
def test_opening_range_reset_unlocks():
or_ind = ta.OpeningRange(2)
or_ind.update((101.0, 102.0, 100.0, 101.0, 0.0, 0))
or_ind.update((102.0, 103.0, 101.0, 102.0, 0.0, 1))
assert or_ind.is_locked()
or_ind.reset()
assert not or_ind.is_locked()
def test_value_area_warmup_equals_period():
assert ta.ValueArea(20, 50, 0.70).warmup_period() == 20
assert ta.ValueArea(10, 30, 0.80).warmup_period() == 10
def test_ehlers_indicators_lifecycle():
# Spot-check a few Family-10 entries beyond what test_new_indicators covers.
series = np.linspace(1.0, 200.0, 200) + np.sin(np.arange(200) * 0.3) * 5.0