- Move lib/trends_IIR/decay/ → lib/numerics/decay/ - Move lib/trends_IIR/edecay/ → lib/numerics/edecay/ - Update Category in Decay.md/Edecay.md from Trends (IIR) to Numerics - Add DECAY/EDECAY entries to lib/numerics/_index.md and docs/indicators.md - Update filter signature .md files and .svg assets - Update trends_IIR signature docs (htit, mama, holt, etc.) - All 163 tests passing, 0 warnings, 0 errors
13 KiB
HTIT: Ehlers Hilbert Transform Instantaneous Trend (also known as HT_TRENDLINE)
| Property | Value |
|---|---|
| Category | Trend (IIR MA) |
| Inputs | Source (close) |
| Parameters | None |
| Outputs | Single series (HTIT) |
| Output range | Tracks input |
| Warmup | 12 bars |
| Signature | htit_signature |
TL;DR
- HTIT (Hilbert Transform Instantaneous Trend) is a trend-following indicator that doesn't rely on simple averaging.
- No configurable parameters; computation is stateless per bar.
- Output range: Tracks input.
- Requires
12bars of warmup before first valid output (IsHot = true). - Validated against TA-Lib, Skender, and Tulip reference implementations where available.
"John Ehlers brought rocket science to trading. Literally. HTIT uses signal processing to find the trend by removing the cycle. It's not smoothing; it's extraction."
HTIT (Hilbert Transform Instantaneous Trend) is a trend-following indicator that doesn't rely on simple averaging. Instead, it uses the Hilbert Transform to measure the dominant cycle period of the market and then computes a trendline that filters out that specific cycle. It adapts to the market's rhythm rather than imposing a fixed period.
Historical Context
John Ehlers, a pioneer in applying DSP to trading, introduced this in his book Rocket Science for Traders. He recognized that markets have cyclic components (noise) and trend components. By identifying the cycle, you can mathematically subtract it to reveal the pure trend.
Most trend indicators (SMA, EMA) are low-pass filters: they let low frequencies (trend) pass and block high frequencies (noise). The problem is that "noise" in markets isn't random white noise; it's often cyclic. A fixed-period SMA might filter out a 10-day cycle perfectly but amplify a 20-day cycle. HTIT solves this by measuring the cycle first, then tuning the filter to kill exactly that frequency.
Architecture & Physics
This is a complex, multi-stage signal processing pipeline. It's not just a formula; it's a machine.
- Smooth: 4-bar WMA to remove high-frequency noise (Nyquist limit).
- Detrend: High-pass filter to remove the DC component (trend) temporarily to isolate the cycle.
- Hilbert Transform: Compute In-Phase (I) and Quadrature (Q) components.
- Period Measurement: Use the phase rate of change (Homodyne Discriminator) to measure the dominant cycle period.
- Trend Extraction: Average the price over the measured dominant cycle period to cancel out the cycle.
- Post-Smoothing: 4-bar WMA on the extracted trend for final polish.
The "physics" here is cancellation. If you average a sine wave over exactly one period, the result is zero. If you average Price (Trend + Cycle) over exactly one cycle period, the Cycle cancels out, leaving only the Trend.
Mathematical Foundation
1. Pre-Smoothing
A 4-tap FIR filter removes high-frequency noise to prevent aliasing before the Hilbert Transform.
\text{Smooth}_t = \frac{4 P_t + 3 P_{t-1} + 2 P_{t-2} + P_{t-3}}{10}
2. Hilbert Transform & Detrending
The signal is detrended and split into In-Phase (I) and Quadrature (Q) components using a 7-tap Hilbert Transform. The coefficients are optimized for market cycles (10-40 bars).
\text{Adj} = 0.075 \cdot \text{Period}_{t-1} + 0.54
\text{Detrender}_t = \left( \frac{5}{52} S_t + \frac{15}{26} S_{t-2} - \frac{15}{26} S_{t-4} - \frac{5}{52} S_{t-6} \right) \cdot \text{Adj}
Q_t = \left( \frac{5}{52} D_t + \frac{15}{26} D_{t-2} - \frac{15}{26} D_{t-4} - \frac{5}{52} D_{t-6} \right) \cdot \text{Adj}
I_t = D_{t-3}
3. Homodyne Discriminator
The phase rate of change is calculated using the complex conjugate product of the current and previous phasors. This is the "Homodyne Discriminator" - a fancy radio term for "measuring frequency by comparing a signal to a delayed version of itself."
\text{Re}_t = (I2_t \cdot I2_{t-1}) + (Q2_t \cdot Q2_{t-1})
\text{Im}_t = (I2_t \cdot Q2_{t-1}) - (Q2_t \cdot I2_{t-1})
The period is derived from the phase angle of this complex product:
\text{Period}_t = \frac{2\pi}{\arctan\left(\frac{\text{Im}_t}{\text{Re}_t}\right)}
The period is constrained to [6, 50] bars and smoothed.
4. Instantaneous Trend
The trend is extracted by averaging the price over the measured dominant cycle period. This is the magic step.
\text{IT}_t = \frac{1}{\text{DC}} \sum_{i=0}^{\text{DC}-1} P_{t-i}
Where \text{DC} is the integer part of the smoothed dominant cycle period.
5. Final Output
The Instantaneous Trend is smoothed again using the same 4-bar WMA to remove any residual stepping artifacts from the integer period changes.
\text{HTIT}_t = \frac{4 \text{IT}_t + 3 \text{IT}_{t-1} + 2 \text{IT}_{t-2} + \text{IT}_{t-3}}{10}
Mathematical Precision & Implementation Philosophy
Like our MAMA implementation, QuanTAlib's HTIT prioritizes mathematical correctness over blind porting.
| Aspect | Other Libraries | QuanTAlib | Rationale |
|---|---|---|---|
| Hilbert Coefficients | 0.0962, 0.5769 |
5.0/52.0, 15.0/26.0 |
Exact fractions avoid rounding accumulation |
| Adjustment Slope | 0.075 |
3.0/40.0 |
Preserves rational arithmetic precision |
| Adjustment Intercept | 0.54 |
27.0/50.0 |
Ditto |
| Arctangent Function | atan(y/x) |
atan2(y, x) |
Proper quadrant handling, no division by zero |
| Period Calculation | 360/atan(...) |
2π/atan2(...) |
Mathematically correct radians |
We use atan2 for robust phase calculation and maintain full double precision throughout the pipeline.
Performance Profile
HTIT is computationally heavier than a simple MA but lighter than MAMA. The main cost is the loop for the Instantaneous Trend calculation, which sums up to 50 past prices.
Operation Count (Streaming Mode, Scalar)
| Operation | Count | Cost (cycles) | Subtotal |
|---|---|---|---|
| Stage 1: Pre-Smoothing (4-tap FIR) | |||
| MUL | 4 | 3 | 12 |
| ADD | 3 | 1 | 3 |
| Stage 2: Detrender (7-tap Hilbert) | |||
| MUL | 4 | 3 | 12 |
| ADD/SUB | 3 | 1 | 3 |
| Stage 3: Q Hilbert Transform | |||
| MUL | 4 | 3 | 12 |
| ADD/SUB | 3 | 1 | 3 |
| Stage 4: I2/Q2 Smoothing | |||
| FMA | 2 | 4 | 8 |
| Stage 5: Homodyne Discriminator | |||
| MUL | 4 | 3 | 12 |
| ADD/SUB | 2 | 1 | 2 |
| Stage 6: Period Calculation | |||
| ATAN2 | 1 | 50 | 50 |
| DIV | 1 | 15 | 15 |
| CMP (clamp) | 2 | 1 | 2 |
| Stage 7: Period Smoothing | |||
| FMA | 1 | 4 | 4 |
| Stage 8: Instantaneous Trend (O(N) sum) | |||
| ADD | ~25 avg | 1 | ~25 |
| DIV | 1 | 15 | 15 |
| Stage 9: Final 4-tap Smoothing | |||
| MUL | 4 | 3 | 12 |
| ADD | 3 | 1 | 3 |
| Total | ~193 cycles |
Dominant costs:
- ATAN2 (50 cycles, 26%) — phase measurement for homodyne discriminator
- IT summation loop (~25 cycles avg, 13%) — O(N) complexity where N = dcPeriod (6-50)
Note: The IT loop iterates dcPeriod times (6-50 bars). The estimate above uses 25 as the average. Worst case (dcPeriod=50) adds ~50 cycles total.
Batch Mode (SIMD Analysis)
HTIT is not SIMD-parallelizable across bars due to:
- Recursive feedback in Hilbert transforms (I2, Q2 depend on previous values)
- Period-dependent IT summation loop (variable iteration count)
- Homodyne discriminator state dependencies
Per-bar optimization with FMA: The 4-tap smoothing stages and Hilbert transforms could benefit from FMA, saving ~4-8 cycles per bar.
Quality Metrics
| Metric | Score | Notes |
|---|---|---|
| Accuracy | 9/10 | Extracts trend by mathematically canceling the dominant cycle |
| Timeliness | 7/10 | Adapts period, but IT averaging introduces inherent lag |
| Overshoot | 8/10 | Generally stable; double WMA reduces oscillation |
| Smoothness | 9/10 | Very smooth trendline due to dual 4-tap WMA stages |
Validation
Validated against TA-Lib, Skender, and Ooples.
| Library | Status | Notes |
|---|---|---|
| QuanTAlib | ✅ Reference | Mathematically correct implementation. |
| TA-Lib | ✅ | Matches HtTrendline exactly (1e-9 precision). |
| Skender | ⚠️ | Matches GetHtTrendline (~0.32% diff). |
| Ooples | ⚠️ | Matches CalculateEhlersInstantaneousTrendlineV1 (~0.25% diff). |
The differences with Skender and Ooples arise from:
- Initialization: How the first few bars are handled.
- Precision: Hardcoded decimals vs exact fractions.
- Period Constraints: How strictly the [6, 50] bounds are enforced during intermediate steps.
C# Implementation Considerations
State Management
HTIT uses a compact record struct for Hilbert Transform state tracking:
[StructLayout(LayoutKind.Auto)]
private record struct State(
double I2, double Q2, double Re, double Im,
double Period, double SmoothPeriod,
double LastValidPrice, int Index
);
Bar correction uses simple state copy (no RingBuffer snapshot needed for state struct):
if (isNew) { _p_state = _state; _state.Index++; }
else { _state = _p_state; }
Multiple RingBuffers
HTIT maintains six separate circular buffers for the multi-stage pipeline:
private readonly RingBuffer _priceBuffer; // 64 elements (for IT sum)
private readonly RingBuffer _smoothBuffer; // 8 elements
private readonly RingBuffer _detrenderBuffer; // 8 elements
private readonly RingBuffer _i1Buffer; // 8 elements
private readonly RingBuffer _q1Buffer; // 8 elements
private readonly RingBuffer _itBuffer; // 8 elements
The price buffer is larger (64) to support IT calculation over up to 50 bars.
Precomputed Constants
High-precision rational constants avoid rounding accumulation:
private const double c1 = 5.0 / 52.0; // ~0.09615385
private const double c2 = 15.0 / 26.0; // ~0.57692308
private const double adjSlope = 3.0 / 40.0; // 0.075
private const double adjIntercept = 27.0 / 50.0; // 0.54
private const double TwoPi = 2.0 * Math.PI;
FMA Usage
Smoothing operations use FusedMultiplyAdd for precision:
_state.I2 = Math.FusedMultiplyAdd(0.2, i2_val, 0.8 * _p_state.I2);
_state.Q2 = Math.FusedMultiplyAdd(0.2, q2_val, 0.8 * _p_state.Q2);
_state.Re = Math.FusedMultiplyAdd(0.2, re_val, 0.8 * _p_state.Re);
_state.Period = Math.FusedMultiplyAdd(0.2, period, 0.8 * prevPeriod);
Stack-Allocated Calculate Method
The static Calculate(Span) method uses stackalloc for zero-allocation batch processing:
Span<double> priceBuffer = stackalloc double[64];
Span<double> smoothBuffer = stackalloc double[8];
// ... etc
const int Mask63 = 63; // Power-of-2 masking for circular index
const int Mask7 = 7;
Memory Layout
| Field | Type | Size | Purpose |
|---|---|---|---|
_priceBuffer |
RingBuffer | ~8B+512B | Price history (64×8B) |
_smoothBuffer |
RingBuffer | ~8B+64B | Smoothed prices (8×8B) |
_detrenderBuffer |
RingBuffer | ~8B+64B | Detrender output |
_i1Buffer |
RingBuffer | ~8B+64B | In-phase component |
_q1Buffer |
RingBuffer | ~8B+64B | Quadrature component |
_itBuffer |
RingBuffer | ~8B+64B | Instantaneous trend |
_state |
State | ~64B | Current Hilbert state |
_p_state |
State | ~64B | Previous state for rollback |
| Total | ~960B | Per indicator instance |
Numerical Robustness
Uses Math.Atan2 for proper quadrant handling in phase calculation, avoiding division-by-zero issues that plague atan(y/x) implementations.
Common Pitfalls
- Warmup: This indicator needs significant warmup (at least 12 bars, ideally 50+) for the feedback loops (period smoothing) to stabilize. Don't trust the first 50 bars.
- Lag: While it adapts, the trendline still lags because it's essentially a dynamic SMA. The advantage is that the period is optimal for the current market condition, not that it has zero lag.
- Complexity: Debugging this is a nightmare. Trust the math.
- Ranging Markets: In a pure range, the "trend" should be flat. HTIT handles this well because the cycle cancellation works best when the cycle is clear.